Global medical societies define reduced muscle mass as an independent criterion for diagnosis of malnutrition
Validated BIA from seca conforms to consensus on diagnostic methods
Previous attempts at optimizing the diagnosis of malnutrition were based primarily on the criteria "non-volitional weight loss" and "low BMI ≤ 20". These criteria, however, have proven to be inadequate in practice, says Michael Johannes Maisch, M.D. and Chief Medical Advisor at seca: "When only weight loss and BMI are taken into account, no consideration is given to edema, which is also a frequent symptom of malnutrition. Water retention distorts the weight and can even effect a weight gain and a higher BMI although malnutrition is present. Consequently, many malnourished patients fall through the cracks."
seca software has included Fat Mass Index analysis since 2017In the consensus report the GLIM defined five criteria for the diagnosis and severity of malnutrition. After a patient has been identified at risk of malnutrition, at least one phenotypic criterion (non-volitional weight loss, low BMI, reduced muscle mass) and one of the etiologic criteria (reduced food intake/assimilation and inflammation/disease burden) must be fulfilled for a diagnosis of malnutrition.
A leading manufacturer of medical body composition analysis devices, seca deals with the subjects of weight and body composition every day and knows how important muscle mass is for the diagnosis of malnutrition. At the beginning of 2017 seca incorporated the Fat-Free Mass Index (FFMI) in the analytical software of the medical Body Composition Analyzer (mBCA) and implemented the cut-offs from the first ESPEN consensus paper . These parameters make it even easier for the user to detect malnutrition by means of Bioelectrical Impedance Analysis (BIA). "We welcome the revaluation of the FFMI as an independent criterion," says Dr. Maisch.
ESPEN General Secretary confirms BIA as a valid method of capturing FFMIProf. Dr. Matthias Pirlich, ESPEN General Secretary, sees the consideration of body composition as a positive development. "The new GLIM criteria for the diagnosis of malnutrition also include the detection of a prognostically significant change in body composition," says Pirlich. "The GLIM consensus takes into account several studies from the past 10 years which have shown that the loss of muscle mass concurrent with a chronic or severe disease is an independent risk factor for a poor clinical course. The Bioelectrical Impedance Analysis is an economical and valid method of measuring the loss of muscle mass or fat-free mass in everyday clinical work."
Type of validation methods of BIA devices determine the qualityThe GLIM consensus names the methods CT, MRI, DXA and BIA as the methods to be used to measure muscle mass. Their practical application, however, is critical. Given the complexity, costs or radiation exposure (CT), MRI and CT are unsuitable for clinical routine use. "DXA too should be looked at critically when it comes to measuring muscle mass," says Dr. Maisch. "DXA significantly overestimates Skeletal Muscle Mass. In a diagnosis of malnutrition with reduced muscle mass, this is naturally counterproductive." Even BIA is not simply BIA. The devices whose measurements of muscle mass have been validated against DXA share the bias of the reference device. You can expect to capture reduced muscle mass accurately only if the BIA device has been validated with whole-body MRI. Users benefit from the simple, fast and radiation-free methods of the BIA when the device's accuracy is assured.“
1 FFMI <17 (male) <15 kg/m2 (female); Cederholm et al., Diagnostic criteria for malnutrition – An ESPEN Consensus Statement. Clinical Nutrition, 34(3), pp.335-340.
2 Bosy-Westphal et al., Quantification of whole-body and segmental skeletal muscle mass using phase-sensitive 8-electrode medical bioelectrical impedance devices. European Journal of Clinical Nutrition (2017) 71, 1061–1067
More information about seca at www.seca.com and the seca science center.
Press Contactseca gmbh & co. kg
Anika Otto; Communications Manager
E-Mail: anika.otto@seca.com
Tel.: +49 40 20 00 00 411
www.seca.com
seca – precision for healthSince 1840 seca has perfected the skill of developing innovative weighing technology combined with practical functions and has become the world's market leader in medical measuring and weighing. seca measuring systems and scales are sold by 16 branch offices and exported to 110 countries. The seca service network guarantees continuous maintenance of the precision instruments. To provide doctors and medical personnel with professional support, seca maintains close contact to users and tailors innovative products to the exact needs of their medical applications. Examples include networked measuring stations that communicate with each other, service and software systems that simplify medical routines and the medical Body Composition Analyzer (mBCA) which uses Bioelectrical Impedance Measurement (BIA) to revolutionize diagnostics and treatment. Ultra-modern production technology, durable materials and a worldwide quality management system ensure top-level product standards.
Contact press office
Contact.
seca press service.
Are you from the press and would like to request information about our company or our products? You can contact our press office directly using the e-mail form.
The fields marked with an asterisk (*) must be filled out. All other information is provided voluntarily.